The connected load first first dims to the previously set atmosphere
and after 3 seconds to the desired atmosphere, which is then
stored in memory.
You have now set the light atmosphere. You can call up the light
atmosphere at any time by pressing the push button.
In 1-push button mode, you can simultaneously call up the light
atmosphere of various light circuits. To this end, you connect
terminals 1 and 3 of the dimmers that control the respective
light circuits.
Mode 4: OFF with 3-second operating time
In this mode, you switch off the light by pressing the push button
for 3 seconds.
Mode 5: OFF with time delay (run time)
In mode 5, you press the push button to switch off the light either
directly or after a period of e.g. 3 minutes. This run time is set during
the programming. You can choose one of the following periods: 0
seconds, 10 seconds, 30 seconds, 1 minute or 3 minutes.
B. Meaning LEDs
Load LED (fig. A)
This LED lights if the load is connected and indicates in which
mode the dimmer is set. reverse phase control or phase control
(the choice is made automatically).
In case of normal operation, the load LED can have the following
meaning: