Resetting The Overheat Protector; Spare Parts; Zurückstellen Der Überhitzungsschutzes; Ersatzteile - Harvia XENIO COMBI CX110C Mode D'emploi

Masquer les pouces Voir aussi pour XENIO COMBI CX110C:
Table des Matières

Publicité

EN
360°
Figure 10.
Sensor's minimum distance from an air vent
Abbildung 10. Mindestabstand des Fühlers zu Luftschlitzen

3.5. Resetting the Overheat Protector

The sensor box (
WX232
sensor and an overheat protector. If the temperature
in the sensor's environment rises too high, the
overheat protector cuts off the heater power.
Resetting the overheat protector is shown in figure
11.
Note! The reason for the protector's activation
must be determined before the button is pressed.

4. SPARE PARTS

1
1 Control panel (CX110C)
2 Temperature sensor
3 Humidity sensor
4 Data cable 5 m
5 Data cable extension (optional) 10 m
6 Circuit board (XT2020)
Es dürfen ausschließlich die Ersatzteile des Herstellers verwendet werden.
180°
) contains a temperature
2
3
We recommend using only the manufacturer's spare parts.
DE
WX232
Figure 11.
Abbildung 11. Rückstellknopf des
3.5. Zurückstellen der Überhitzungsschutzes
Das Fühlergehäuse (WX232) enthält einen Tempe-
raturfühler und einen Überhitzungsschutz. Wenn
die Temperatur in der Umgebung des Temperatur-
fühlers zu stark ansteigt, unterbricht der Überhit-
zungsschutz die Stromzufuhr. Das Zurücksetzen
des Überhitzungsschutzes wird in Abbildung 11
dargstellt.
Achtung! Bevor Sie den Knopf drücken, müssen
Sie die Ursache für die Auslösung des Überhitzungs-
schutzes ermitteln.

4. ERSATZTEILE

4
5
Bedienfeld (CX110C)
Temperaturfühler
Feuchtigkeitsfühler
Datakabel 5 m
Verlängerungskabel (wahlweise) 10 m
Platine (XT2020)
Reset button of the overheat
protector
Überhitzungsschutzes
6
WX381
WX232
WX325
WX311
WX313
WX356
37

Publicité

Table des Matières
loading

Table des Matières