Télécharger Imprimer la page

GiBiDi BE24 Instructions Pour L'installation page 16

Masquer les pouces Voir aussi pour BE24:

Publicité

Les langues disponibles

Les langues disponibles

16
UK
6 - ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
1
2
M1
3
4
5
6
7
8
M2
9
10
11
12
13
M3
14
15
16
17
18
19
20
21
22
23
M4
24
25
Signal
Description
M1+
Motor 1+
M1-
Motor 1-
M2+
Motor 2+
M2-
Motor 2-
+
Electric lock power supply
EL+
- Electric lock power supply 12V
EL-
+ FLASHLIGHT power supply 24 VDC MAX 10W.
LAMP/SPIA
- FLASHLIGHT power supply 24 VDC MAX 10W.
LAMP/SPIA
+24Vdc
External accessory power supply
+ACC
External accessory power supply common
-ACC
Motor 1 ENCODER +5VDC power supply.
5V
Motor 1 ENCODER signal.
S1
Motor 1 ENCODER power and signal common.
COM
Motor 2 ENCODER +5VDC power supply.
5V
Motor 2 ENCODER signal.
S2
Motor 2 ENCODER power and signal common.
COM
START input (N.O.).
START
PEDESTRIAN input (N.O.)
PED
The Pedestrian manoeuvre is carried out with Automatic logic, not modifiable.
PHOTOCELL 1 input (N.C.). Input active only during closing.
It stops and inverts the motion, opening the gate completely. If the gate is closed, it does
PHOTO 1
not affect its functioning. If intercepted during pause, it reloads the pause time.
PHOTOCELL 2 input (N.C.). Input active during both opening and closing.
If intercepted, it immediately stops the motion and holds it stopped until the photocell
PHOTO 2
is freed. Upon release, motion always restarts in opening. If intercepted during pause, it
reloads the pause time.
STOP
Programmable INPUT (STOP – EDGE).
SAFETY
COM
Accessory common.
Accessory common.
COM
Input IN1 (N.O.) fo
Operation:
Gate closed
During total opening
During pedestrian opening
Gate completely open
IN1
Gate open form Pedestrian
During closing
WARNING: remember to enable both the automatic reclosure, if you want, and the
condominium logic, if you do not want any interaction with START command during
the opening phase.
IN2
Unused imput.
12V
MAX 10W
r the connection of external devices, for instance clock
total opening
IRRELEVANT
total opening
recharge the automatic closing time, if enabled,
otherwise IRRELEVANT
total opening
total opening
BE24
.

Publicité

loading