Atlantis Host Power 1001 Mode D'emploi page 65

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model
Power Rating(VA)
Power Rating(W)
INPUT
Voltage:
Frequency:
OUTPUT
Voltage:
Frequency:
AVR
Waveform
TRANSFER Line/Battery
EFFICIENCY
BATTERY
Voltage
Capacity
Quantity
Recharge Time
Type
INDICATORS(Display)
PROTECTION
CONNECTIONS
Backup Time
MECHANICAL
166-275V [220V(±25%], DIP Switch selectable
Sealed Maintenance Free Lead Acid VRLA Type
Utility Normal, Backup, Battery Low and Battery
Dimensions
(WxHxD):
A03-HP2001
2000
1200
50Hz±5%
220V(±13%) [AC] / 220V(±7%) [INV]
50Hz (±1%)
Pure SineWave (<3% Linear Load)
Less than 4 ms (typical)
Total Efficiency Over 80%
12V/7.2Ah
3-5 hours to (90%)
Fault conditions
Overload AC (>110%): Buzzer continuously
alarms & shuts down after 10 minutes
Overload Inverter (>100%): UPS shuts down
after 10 seconds
Short Circuit INV: Electric Circuit
Short Circuit AC: Input Fuse & Electric Circuit
Battery Over-drain Two stages: Controlled
Battery Low Warning & Cut Off
Modem/Network RJ45 / RJ11
Spike Suppression Meets EN61000-4-5
Noise Suppression Meets EN50991-1
Output 6xIEC (Battery Power Supplied)
Computer USB/RS232
10 to 30 mins for typical PC Load
173 x 247 x 427 mm
65
A03-HP3001
3000
1800
Built-in
24VDC
12V/9.0Ah
4