4. Specification and ordering information
Significance of digits 1. to 7.
Order Code
1. Version of the transmitter
Standard,
Measuring output non-intrinsically safe
EEx ia IIC T6, ATEX
Measuring output intrinsically safe
Ex ia IIC T6, FTZU (Czech republic),
Measuring output intrinsically safe
2. Sense of rotation
Calibrated for sense of rotation clockwise
Calibrated for sense of rotation
counterclockwise
V characteristic
Calibrated for both senses of rotation
3. Measuring range (measuring input)
0 ... 10
°
0 ... 30
°
0 ... 60
°
0 ... 90
°
0 ... 180
°
0 ... 270
°
Non-standard
0...≥ 5 to 0...< 270
V characteristic
4. Output signal (measuring output)
0 ... 1 mA, 3 or 4-wire connection
0 ... 5 mA, 3 or 4-wire connection
0 ... 10 mA, 3 or 4-wire connection
4 ... 20 mA, 2-wire connection
or
0 ... 20 mA, 3 or 4-wire connection
4 ... 20 mA, 3 or 4-wire connection
0 ... 20 mA, 4-wire connection
Non-standard, 3 or 4-wire connection
0 ... > 1.00 to 0 ... < 20 mA

5. Technical data

Measuring input
0...≥ 5 to 0... ≤ 270
Measuring ranges:
(without gear)
Preferred ranges
0...10, 0...30, 0...60, 0...90,
0...180 or 0...270
0...≥ 10
(with additional gear)
Measuring output
Output variable I
:
Load-independent DC current,
A
proportional to the input angle
22
707 –
1
2
6
1
2
3
4
1
2
3
4
5
6
°
9
A
A
B
C
D
E
F
Z
°
°
° to 0...1200 turns
Order Code
5. Power supply
24 ... 60 V DC/AC,
with electric isolation
85 ... 230 V DC/AC,
with electric isolation
12 ... 33 V DC,
without electric isolation
12 ... 30 V DC (Ex),
without electric isolation
6. Mounting mode
Without foot, without flange
With foot (mounted)
With flange (mounted)
7. Material of transmitter rear cover /
Routing of connecting cable
Plastic / connector
less cable plug, socket mounted
for cable routed to the rear
Plastic / connector
less cable plug, socket mounted
for cable routed to the front
Plastic / connector
with cable plug, cable routed
to the rear
Plastic / connector
with cable plug, cable routed
to the front
Metal / screw terminals and cable glands
Note
The remaining order code digits concern special
features, e.g. the ancillary gear for extending the
measuring ranges.
Standard ranges:
0...1 mA,
3 or 4-wire connection
0...5 mA,
3 or 4-wire connection
0...10 mA,
3 or 4-wire connection
4...20 mA, 2 wire connection
or
0...20 mA, 3 or 4-wire connection
adjustable with potentiometer
4...20 mA,
3 or 4-wire connection
0...20 mA, 4-wire connection
Non-standard ranges: 0...> 1.00 to 0...< 20 mA
3 or 4-wire connection
707 –
1
2
A
B
0
1
2
1
2
3
4
5

Publicité