Les langues disponibles

RECEIVER (BLINKING SYMBOLS)
7 SEGMENTS DISPLAY
SYMBOL
MEANING
Displayed alternatively
F
to the error code
3
Internal error
4
A
OSSD1 - OSSD2 short-
6
OSSD static outputs error
5
Interfering dangerous
Emitter detected.
The Receiver is able to
I
receive simultaneously the
beams from two different
Emitters.
(only for MASTER
models)
U
SLAVE connections
incorrect
(only for MASTER and
STANDARD models)
0
Overload of the OSSD static
outputs
(only for MASTER and
STANDARD models)
Blanking configuration
H
changed without system
RED
ON
ON
ON
ON
ON
circuit
ON
ON
ON
ON
ON
restart
LED
GREEN
YELLOW
OFF
OFF
OFF
OFF
Send the equipment for repair
OFF
OFF
to SCHMERSAL.
OFF
OFF
Take action in one of the following
ways:
OFF
OFF
Take action in one of the following
ways:
OFF
OFF
Carefully locate the interfering
Emitter and take action in one of the
following ways:
OFF
OFF
Carefully check the MASTER-SLAVE
OFF
OFF
connections.
Carefully check the connection of
OFF
OFF
terminals 1 and 3 (OSSD) on the
connector.
OFF
OFF
Operate a system restart
REMEDY
(STANDARD and MASTER
MODELS)
Carefully check the connection of
terminals 1 and 3 (OSSD) on the
connector.
(SLAVE MODELS)
Send the equipment for repair to
SCHMERSAL.
(STANDARD and MASTER
MODELS)
Carefully check the connection of
terminals 1 and 3 (OSSD) on the
connector. If necessary, adjust
load reducing the current required
to max 500 mA (2 F).
(SLAVE MODELS)
Send the equipment for repair to
SCHMERSAL.
Reduce the emitter range from
high to low.
Switch the position of the Emitter
and Receiver.
Move the interfering Emitter to
avoid this illuminating the
Receiver.
Shield the beams coming from the
interfering Emitter using opaque
protections.