3. Lift off the fan unit (Pos. 1) and place it next to the filter unit (Pos. 2).
Ensure that the seal is not damaged.
4. Using a compressed air gun, blow off the entire filter cartridge (Pos. 6)
from top to bottom at a distance of approx. 5 cm. The dust deposits on
the untreated air side are blown off and fall into the dust collection
container.
5. Reassemble the product in reverse order, placing the fan unit (Pos. 1) on
the filter unit (Pos. 2) and closing the two clamp fasteners (Pos. 4),
making sure that the seal is correctly seated.
6. Connect the product to the power supply and put it back into operation.
(see also "Commissioning" chapter)
NOTE
Damage to the filter cartridge
The filter cartridge may only be cleaned with clean, dry and oil-free
compressed air at a maximum pressure of 3 bar.
Too much pressure and insufficient distance (less than 5 cm) can
damage the filter cartridge.
1502937-00
Fig. 24: Cleaning the filter cartridge
- 70 -