NOTE: In the event that the equipment has to be transported; the refrigerant bottle scale
should be locked in place as follows:
-
Use two size 10 wrenches.
-
Tighten the nut [2] almost completely onto the screw [1].
-
Insert the knurled washer [4] onto the screw [1].
-
Turn the screw [1] just a few times on the threaded bush [6].
-
Switch the machine on.
-
Tighten the screw [1] until the display signals ZERO availability.
-
Tighten the nut [2] forcefully (using the second wrench to block the screw [1]).
-
Check that the screw [1] is actually locked, if necessary repeat the locking operation
from the beginning.

THE MACHINE

BASIC COMPONENTS

Refer to Figures 5, 6, 7 and 8.
a) Control consoles
h) Wheels
m) Used oil container
bi) Oil scale
e) Drying filters
i) Main switch
k) Fuse
f) Vacuum pump

CONTROLS AND CONTROL SYSTEM

Refer to Figure 9.
A1) High pressure gauge
A3) Keyboard
A5) Printer

FUNCTION SELECTOR KEYBOARD

STOP: Press to interrupt the operation being performed in the case of the principal functions--
recovery - oil discharge - vacuum/oil charging - charging. Press START to resume operation
from the point of interruption. Pressing STOP during an alarm state, error state, or end-of-
operation silences the audible alarm.
RESET: Press to interrupt the operation being performed. The procedure will be restarted from
the beginning.
ENTER: Press to confirm the procedure or operation flashing on the LCD.
↓: Press to move downward from one procedure or operation to another within a menu.
↑: Press to move upward from one procedure or operation to another within a menu.
START: Press to launch the procedure or operation shown on the display.

ALARMS

HIGH PRESSURE ALARM: Beeper and LCD advise when the pressure reaches 290 psi (20
bar). The recovery operation is automatically interrupted.
FULL BOTTLE ALARM: Beeper and LCD advises when the bottle is filled to more than 80% of
maximum capacity; that is, 40lbs (17kg).
interrupted (to cancel this alarm, charge one or more A/C systems before recovering any more
refrigerant).
INSTRUCTIONS MANUAL
z) Tracer bottle
b) Taps
l) High/Low Pressure threaded connectors
n) New oil container
d) Bottle
o) Electronic scale
ps) Serial port
j) Socket for electrical supply plug
c) Moisture indicator
r) Bottle heater
A2) Low pressure gauge
A4) LCD, 4 lines, 20 characters
The RECOVERY operation is automatically