Press key 1 to enable dye injection or 0 to disenable and press START to continue. After
enabling the dye, recalibrate the oil scale.

Flush KIT

Refer to Figure 12:
K1: system or component to be washed
K3: first connection terminal
K5: one-way valve
K7: inlet hose to system
K9: one-way valve

USING THE FLUSH KIT (FK300)

Attention: Flushing an R12 system with the machine is permissible only after having performed
the operations listed below. Recover the R12 with another recovery device for R12. Perform
vacuum with the machine for at least 20 minutes before flushing. Connect terminal k3 of the kit
to the outlet of the component or system to be flushed. Connect terminal k8 of the kit to the
inlet of the component or system to be flushed. Connect the low-pressure quick-connect
coupling of the machine to male coupling k6 of the flush kit. Connect the high-pressure quick-
connect coupling of the machine to male coupling k10 of the flush kit
Switch the machine on. The MAIN MENU will appear after a few seconds.
Select NEXT MENU::
Select SYSTEM FLUSHING:
Press START.
Press START.
INSTRUCTIONS MANUAL
TRACER-DYE ENABLING
<Press 1 enabled>
Press 0 disabled
START to continue
K2: outlet hose from system/component
K4: filter for solid particles
K6: LP male quick-connect coupling
K8: second connection terminal
K10: HP male quick-connect coupling
AUTOMATIC PROCEDURE
ASSISTED PROCEDURE
<NEXT MENU>
Gas Avail
xxxxx g
CALIBRATION
DATA AND CONFIGURAT.
SERVICE ALARM
BOTTLE FILLING
<A/C SYSTEM FLUSHING>
Connect the Flush kit as
explained in the manual
Press START
SYSTEM Flushing
Open high and low pressure
and
press START
-28-