Télécharger Imprimer la page

Delabie TEMPOSTOP Mode D'emploi page 9

Masquer les pouces Voir aussi pour TEMPOSTOP:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Exposed shower kit (ref. 749001) (Fig. F):
Fix the shower head a so that the nozzle b is 2.10m from
the shower tray or tiled floor.
Assemble the shower column c and the valve e.
Place the white PVC tubes inside the column c.
Insert the whole assembly fully into the hole in the shower head a.
Fix the shower head a to the wall (the rawl plugs should be suitable
for the type of wall).
Fix the collar d over the central joint. Fix the collar d and the valve e
to the wall (use rawl plugs that are suitable for the type of wall).
Connect the water supply and check that the connections are watertight.
Activate the valve several times to stabilise the timing.
Panel-mounted models:
Drill a hole Ø 56mm.
Insert the valve through the panel, placing the back-nut behind the panel.
Tighten the wall plate against the valve with the panel between
the back-nut and the wall plate.
Tighten the 3 screws on the back-nut using a 3mm Allen key.
Connect the water supply and activate the valve several times
to stabilise the timing.
Cross models (Fig. E):
Drill a hole Ø 21mm for the control k and Ø 5.5mm for the locking
screw l.
Mount the control k through the wall. Tighten and lock the nut j
in place with the washer.
Tighten the back-nut i and the connection nut h against the nut j.
Ensure that the push-button m is not activated, then cut the control k
so that it fits flush against the connection nut h.
Unscrew the connection nut h from the control k and screw
onto the valve f.
Screw together the connection nut h and the valve f onto the control k.
Retain 1mm of play between the control k and the valve f. The windows
g on the connection washer h allow the play distance to be controlled.
Tighten the back-nut i.
For models with spouts or shower heads: install the spout or shower
head through the partition (drill a hole Ø 21mm and 5.5mm
for the locking screw) and tighten the nut onto the fixing flange.
Connect the water supply and activate the valve several times
to stabilise the timing.
EN

Publicité

loading

Ce manuel est également adapté pour:

Tempomix 2Tempogenou