Operation and function

The green lamp is on when the appliance is connected to the power supply.
Starting procedure
Connect the mains lead to the power supply
/voltage stabilizer.. The green lamp must
light (fig. 11) to indicate that the appliance
is operating. The electronic thermostat
makes a self test, 20 seconds before the
compressor starts.
Temperature control
It is recommended to check the inside
temperature with an accurate thermometer
twice a day. The inside temperature must
be checked regularly according to WHO's
standards and specifications.
4
+
°C
Cool down of the appliance
Before the appliance is loaded with
vaccines the ice-lining must be frozen. To
ensure that the ice-lining is frozen do the
following:
1. Place a thermometer in the top basket.
2. Let the refrigerator run for at least 48
Hours before loading vaccine.
3. Check the temperature in the vaccine
compartment
(must be between +2° and +8°C).
The temperature in the vaccine
compartment must always be monitored
on the thermometer and be within the
range +2° to +8°C. Due to tolerance of the
thermostat you should always control the
temperature during cool down.