PARTS IDENTIFICATION
Left side
Duct D
(Cold outlet)
Front filter
(Inlet)
Drain Hose
pocket
Wheel casters
Front and Right Side View
Touchpad
temperature
controls
Duct A
(Heat
inlet back
of unit)
Cord
pocket
Wheel casters
Back and Left Side View
07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc.
(Shown, below)
Touchpad
temperature
controls
Duct B
(Heat
outlet)
Condenser
Back housing
(filter set located
inside)
Right
side
Rotomolded
shell
Rotomolded
shell
Left side
OPERATING INSTRUCTIONS
G
S
ETTING
TARTED
P
:
LACEMENT
For cooling or heating, place at least one EB1400 per room.
1.
Place the unit on a level surface.
2.
Make sure the System switch is set to Off then plug power
cord into a standard 115v grounded outlet.
3.
Set the digital temperature controls needed to function
(see below).
4.
Check for proper operation before leaving the unit
unattended. Do not move or carry the EB1400 when it is
running or plugged in.
O
R
PERATING
ANGE
Recommended operating range is between 60° – 115° F.
The EB 1400 will not function properly when operating in
environment with temperatures outside this range.
C
T
C
YCLE
IMES AND
OMPRESSOR
The EB1400 thermostat includes an automatic compressor
protection feature to avoid potential damage to the cooling
system from short cycling. This thermostat automatically
provides a 5-minute delay after turning off the cooling system
output to protect the compressor. This protection is also
present while operating the unit in heating applications.
Important Notes:
If unit loses power or gets unplugged during
operation, operator MUST wait 5 minutes before
plugging unit back in or risk damaging the compressor
or tripping the circuit breaker in the facility.
Always turn the System switch to OFF before
unplugging.
If the System setting is adjusted during operation the
unit will automatically delay 5 minutes before start-up.
When switching unit from cooling to heating or
heating to cooling operator must adjust setpoint
temperature.
T
P
ESTING AND
ROGRAMMING
D
C
IGITAL
ONTROLS
Up
Cool
Off
2
P
ROTECTION
T
HERMOSTAT
Digital screen
Heat
Auto
Reset
Down
Fan
On