ADJUST THE WATERLINE
Adjust the tank water level to the proper marked waterline
by rotating the threaded rod clockwise to raise the water
level or counterclockwise to lower the water level as
needed.
Carefully install the tank cover.
INSPECT AND FINALIZE INSTALLATION
Open the supply shut-off valve, and check all connections
for leakage. If the connections have been properly
assembled, a slight re-tightening of the nuts should stop
any leakage.
Periodically check all bowl and tank connections for
leakage for several days following installation.
Install the toilet seat according to the seat manufacturer's
instructions.
Plug the toilet electrical cord into a Class A ground-fault
circuit-interrupter (GFCI).
ENSURE PROPER OPERATION
This toilet is equipped with dual-flush operation, which
allows for both 1.1-gallon (4.2 L) and 1.6-gallon (6 L) flush.
Make sure both flush functions operate properly.
Set the tank cover in place on the tank.
TROUBLESHOOT AS NECESSARY
Use the owner's manual packed with this toilet to
troubleshoot the system.