Télécharger Imprimer la page

Kohler SAN RAPHAEL POWER LITE K-3398 Instructions D'installation page 2

Masquer les pouces Voir aussi pour SAN RAPHAEL POWER LITE K-3398:

Publicité

Les langues disponibles

Les langues disponibles

ROUGHING-IN
1/2"
(1.3cm)
30" (76.2cm)
3"
(7.6cm)
12" (30.5cm)
INSTALLATION
TO REMOVE THE EXISTING TOILET
Turn off the water supply. Flush the toilet, and use a
sponge to remove the remaining water from the tank and
bowl. Disconnect the supply shut-off valve (if present),
and remove the old tank and bowl.
Use a putty knife to remove the old gasket from the floor
and closet flange. Remove and discard the old T-bolts.
NOTICE: If you are not going to install the new toilet
immediately, temporarily stuff a rag in the closet flange.
Install two new 5/16" diameter T-bolts into the closet
flange.
A
1013091-2-
2-3/4"
(7cm)
15"
(38.1cm)
C L OF OUTLET
3/8" N.P.S. SUPPLY
19-1/4" (48.9cm)
20"
(50.8cm)
2-5/8"
(6.7cm)
6-1/2"
(16.5cm)
Fig. #1
T-Bolts
2
RECEPTACLE
FRONT OF BOWL
6"
(15.2cm)
10-1/4" (26cm)
3" (7.6cm)
Closet Flange
Fig. #2
Closet Flange
Fig. #3
Kohler Co., Kohler, WI U.S.A.
16-5/8"
(42.2cm)
4-3/4"
(12.1cm)