STANDARDS AND RECOMMENDATIONS FOR DISPLAY
COUNTERS WITH R290
- PROPANE - REFRIGERANT GAS
ZOIN SRL refrigerated display counters with R290 gas contain
a quantity of gas of less than 150 g.
It is however necessary to take the following precautions:
- Do not obstruct the vents.
- Do not use mechanical devices or other means to
accelerate the defrosting process other than those
recommended by the manufacturer.
- Do not store explosive substances inside the units, such as
pressurised containers fi lled with fl ammable propellants.
- All repairs must always be carried out by qualifi ed
personnel complying with the safety standards for this
type of gas.
- All equipment used for such activities must be
suitable for this type of gas.
- When replacing components, these must only be
replaced with original components approved for the specifi c
use.
- The disposal of the counter should be entrusted to a
specialist disposal centre in accordance with the laws of
the country of installation.
WARNING: DISPLAY COUNTERS FILLED WITH
R290 REFRIGERANT
The R290 refrigerant gas is compatible with the environment
but highly fl ammable. Pay the utmost attention during the
transport, installation and disposal of the counter, to avoid
damage to the pipes of the refrigerant circuit.
18
Keep the counter away from free flames or sources of ignition.
IN CASE OF DAMAGE
Keep the counter away from free fl ames or sources of
ignition
Thoroughly ventilate the area for a few minutes. Switch off
the counter and disconnect the power plug. Contact
customer service. The more refrigerant is inside the unit,
the larger the environment where it is located must be. In
smaller environments leaks can lead to the formation of a fl
ammable air/gas mix. The volume of the room where the
counter is located must be at least 19 m³ for every
refrigerant system present.
The cooling circuit contains pressurised R290 gas. It can
explode if heated.
THIS PRODUCT CONTAINS HFC, A COOLANT WITH A
HIGH
GREENHOUSE
HERMETICALLY SEALED UNIT AND THE CO-OLANT LOAD
IS LESS THEN 3 KG.
EFFECT
POTENTIAL,
IN
A