01-01RBC-AMS41E_EN.fm Page 11 Friday, April 18, 2008 9:53 AM
7
Set what is to be operated at the time which was
set in step 6.
* The settings can be established in any sequence.
The functions will differ depending on the model and
system.
I. Selecting and setting operation/stop
Each time the
appears on the timer function display changes in
the following sequence. Stop pushing the button
when the desired operation blinks on the display.
(No display)
Operation
continue
II. Selecting and setting the operation mode
Each time the
appears on the operation mode display (1)
changes in the following sequence. Stop pushing
the button when the operation mode blinks on the
display.
Operation mode
(No display)
Auto
III. Setting the temperature
Each time the TEMP
pushed, what appears on the numeric display
changes in the following sequence. Stop pushing
the buttons when the target temperature to be set
blinks on the display.
Push
4 seconds
or more
Frost protection
operation
Push
4 seconds or more
IV.Setting the restriction on the button operations
• Each time the
button (43) is held down, the central control
display changes from off to blinking or vice versa.
To place the restriction on the button operations,
ensure that the display is blinking.
* The
button (32),
TEMP
and
whose operation will be restricted by this setting.
For further details, refer to the "Selecting the
remote controller functions" section.
button (48) is pushed, what
Operation
Operation
stop
start
button (34) is pushed, what
Fan
Cooling
Heating
Dry
and
buttons (49) are
or
button (34) is pushed while the
button (34) and
buttons (49) are the buttons
Scheduled operations
V. Setting the save operation
Each time the
button (38) is pushed, the
numeric display and save operation display
change in the following sequence. Stop pushing
the button when the desired save operation mode
(mode 0 to 3) blinks on the display.
Mode 0
Mode 1
Mode 2
Save operation
Description
mode
Mode 0
No save operation
Mode 1
Save operation with 75% upper limit
Mode 2
Save operation with 50% upper limit
Mode 3
Compressor shutdown
8
Push the
button (42), and enter all the items in
steps I to V above and the operation time
together.
• The display of all the setting items changes from
blinking to lighted.
9
In addition:
I. To input the settings into the different program
number for the same day of the week, repeat the
operations from step 4.
II. To move to a different day of the week and input
the program, repeat the operations from step 2.
10
Finally, push the
button (46) to return to the
original screen.
• An underbar is displayed under the selected day of
the week.
Mode 3
EN
11