Les langues disponibles

removed before the unit is switched on. Overnight operation in
drink mode also eliminates possible ice accumulation from
condensation all around the bowls.
7 Mixers must not be turned off when frozen product is in the
bowl: if not agitated, the product may freeze to a solid block of
ice. If the mixers are turned back on in this situation, damage to
the mixers and their motor may result. Therefore, mixers may
be restarted only after product is melted.
8 The dispenser is equipped with a magnetic coupling by
which the gear motor (located outside the bowl) drives the
mixers (inside the bowl).
The magnetic drive operates as an "intelligent clutch" able
to automatically disconnect the mixers in case they are seized
by ice or other causes.
This inconvenience can be soon noticed since an intermittent
dull noise warns that mixers are still.
In this case it is necessary to unplug immediately the
dispenser, empty the bowl and eliminate the cause of seizing.
9 The dispenser must be able to emit heat.
In case it seems excessive, check that no heating source is
close to the unit and air flow through the slotted panels is not
obstructed by wall or boxes. Allow at least 15 cm (6") of free
clearance all around the dispenser.
10 The product is for use with confectionery only.
9 CLEANING AND SANITIZING PROCEDURES
1 Cleaning and sanitizing of the dispenser are recommended
to guarantee the conservation of the best product taste and the
highest unit efficiency. This section is a procedural guideline
only and is subject to the requirements of the local Health
Authorities.
2 Prior to the disassembly and cleaning, the machine must be
emptied of product. To do this proceed as follows:
- set the power switch to I position
- set mixer/refrigeration switch(es) to I position (Soft Drink
mode)
- place a pail under each faucet and drain all product from
bowls
- set all control switches to the 0 position
9. 1 DISASSEMBLING THE RECOVER
(OPTIONAL)
1 Place the right-hand part of the recover on a surface. Place
the container inside it.(see figure 5)(see figure 6).
2 Put the left-hand part of the recover into position and make
sure that it fits into the illustrated groove. Click the two parts
together. (see figure 7)(see figure 8).
18
figure 5
figure 6
figure 7
figure 8

Publicité