6.10 Connection to the housing
(MAXIMUS MHX)
To install electrical connections between
the products, use the communication
boxes by null, MBX or MBA, alternatively
use an explosion-proof junction box with
equivalent characteristics.
transformer
power supply
Solenoid valve
Explosion-proof
junction box
Fig. 20
transformer
power supply
Explosion-proof
junction box
Connection of
the pressure
switch to an
alarm contact of
the main electric
box.
Fig. 21
16
Safety
Solenoid valve
Safety
Solenoid valve
Pressure switch
(only in versions
with one)
6.10.1 Connection of the solenoid valve
to the housing (MAXIMUS MHX)
The Washer relay in the MHX is suitable for
voltages up to 30Vac or 60Vdc. Turn off one
of the supply poles of the solenoid valve
via the Washer relay (terminal J11) of the
MHX. Consult the housing manual.
Connect as in the diagram below (Fig. 22, page 16).
The solenoid valve can be powered
to 24Vac or 24Vdc with an isolated
transformer or isolated converter.
The polarity of the voltage, applied to the
power terminal, is irrelevant.
Fig. 22
6.10.2 Connection of the pressure
switch to the housing (MAXIMUS MHX)
The housing does not have a prearranged alarm
input.
Connection of the pressure switch to an alarm
contact of the main electric box.