seat (2) (see figure 3).
figure 3
8
Gravity faucet: extract the piston (1) and
then remove the dispensing handle (2-3) (see
figure 4).
figure 4
9
Slide drip tray out and empty it.
5. 3. 2 CLEANING
IMPORTANT
Do not attempt to wash any machine com-
ponents in a dishwasher.
ATTENTION
Before any disassembly and/or cleaning
procedure make sure that the dispenser is
disconnected from its power source by
unplugging it or switching off the 2-pole
wall breaker.
1
Prepare at least two gallons of a mild
cleaning solution of warm (45-60 °C 120-140 °F)
potable water and dishwashing detergent. Do not
use abrasive detergent.
Important: if present, follow label directions, as
too strong a solution can cause parts damage,
while too mi ld a solution will not provide
adequate cleaning.
IMPORTANT
In order to prevent any damages to the
dispenser use only a detergent suitable
with plastics parts.
2
Using a brush, suitable for the purpose,
thoroughly clean all disassembled parts in the
cleaning solution.
ATTENTION
When cleaning the machine, do not allow
excessive amounts of water around the
electrically operated components of the
unit. Electrical shock or damage to the
machine may result.
3
Rinse all cleaned parts with cool clean water.
5. 3. 3 SANITIZING
Sanitizing should be performed immediately
13