Télécharger Imprimer la page

Kohler K-1188 Guide D'installation page 11

Masquer les pouces Voir aussi pour K-1188:

Publicité

Les langues disponibles

Les langues disponibles

Both junction boxes
should be wired as shown.
Each requires a separate
supply.
Ground (Green with
Yellow Stripe)
Blue
Supply
Electrician to
provide suitable
strain relief
8. Make the Electrical Connections
NOTE: The whirlpool model number is printed on a label near the whirlpool pump. This label also
identifies the electrical rating of the whirlpool. All whirlpools come equipped with a wiring junction box
and will only operate at 220 V-240 V and at 50 Hz or 60 Hz.
WARNING: Risk of electric shock. To reduce the risk of electric shock, connect the pump to a
properly grounded Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-Breaker (ELCB).
This will provide additional protection against line-to-ground shock hazard. A 220/240 V, 20 A, 50/60
Hz dedicated circuit is required for the pump, and a second 220/240 V, 50/60 Hz, 20 A dedicated
circuit is required for the heater.
CAUTION: Risk of electric shock. All services must have a Class A Ground-Fault Circuit-Interrupter
(GFCI) or ELCB which will provide additional protection against line-to-ground shock hazard. A
dedicated service is required for the overflowing bath.
The overflowing bath controls and system have been pre-wired at the factory using 220/240 V
hardwire. A licensed electrician should make one routine service connection to the junction box
located adjacent to the pump, and a second routine service connection for the heater junction box.
Connect service to the junction box.
Provide a separate equipment earthing conductor for the earth lug located inside the junction box.
The earthing conductor must not be connected to any current-carrying conductor. Follow local
electrical codes.
Bond in accordance with national and local codes.
One 220/240 V, 50/60 Hz, 20 A dedicated circuit is required for the pump control. A second 220/240
V, 50/60 Hz, 20 A dedicated circuit is required for the heater. Provide a Class A Ground-Fault
Circuit-Interrupter (GFCI) or ELCB.
Follow all local electrical codes.
NOTE: Your wiring harness includes an antenna for the remote control. Do not alter or damage this
antenna during installation.
Kohler Co.
Bond in accordance with
national and local codes.
Wire Connectors
From Control
or Heater
Brown
From Control
60 Hz 50 Hz
or Heater
L1
L1
Brown
L2
N
Blue
Heater (models may vary)
inline (shown) or T-style
(not shown)
Junction
Box
Control
11
Heater
Junction Box
Wiring
Harness
Heater
Electrical Cord
Pump Electrical
Cord
1019731-2-B

Publicité

loading

Ce manuel est également adapté pour:

K-1189