Inside of Bath
2. Spout Orientation
When performing this installation:
Verify correct spout orientation before securing the base to the
floor.
Connect the faucet to the base with screws and washers through
the flange. Orient the spout to the inside of the bath.
Rotate the base if necessary by loosening the screws to verify the
supplies are in line with the base inlet connections. You may have
to modify the supply lines.
The cold supply should be connected where the blue mark or the
notch is located.
Test the handle to verify full rotation will not interfere with the
bathing fixture or the back wall.
Kohler Co.
Finished Floor
5
1144501-2-E