In line with Decree No. A2/1984 (III.10.) BkM-IpM, it is certifi ed that our
appliances conform to the following technical specifi cations.
Use
Placing
Volume [L]
Voltage [V]
Protection grade
Heating power [W]
Heater type
Current input [A]
Heat-up time from 15 ºC to 65 ºC [h]
Standby energy consumption 65 ºC-on [kWh/24h]
Water connection
Nominal operating pressure [MPa]
Integrated safety and regulator elements
Other protection
Contact protection rating
Main regulations applicable to the product
Storage and transport requirements

10. TECHNICAL DATA

Closed system hot water storage container
Wall mounted vertical
30
50
80
120
230V/50Hz
IP X4
1800
Ceramic heater
8,2
0,92
1,8
2,9
0,96
0,77
0,82
1,38
G1/2
0,6
Temperature regulator, temperature limiter,
combined safety valve
Corrosion protection with active anode
I.
MSZ EN 60335-1, MSZ EN 60335-2-21
MSZ EN 60721-3
EN
150
195
2400
11
4,2
4,3
5,5
1,59
1,97
39