INSTALLATION

LOCATION
1. Ventilation
The position you select for the freezer should be well-ventilated and
cool. Do not locate the freezer near a heat source such as a cooker or
boiler, and avoid situating it in direct sunlight, thus guaranteeing the
refrigeration effect while saving energy consumption. Do not locate the
freezer in a damp place, in order to prevent the freezer from rusting
and leaking electricity. The area of the total space of the room in
which the freezer is installed, when divided by the refrigerant charge
amount of the freezer, should not be less than 8 g/ M³.
Note!
• The amount of refrigerant contained in this freezer can be found on
the nameplate.
2. Heat dissipation space
When working, the freezer gives off heat to its surroundings.
Therefore, at least 30mm of free space should be left on the top,
more than 100mm on both sides, and more than 50mm at the back of
the freezer.
31