STOPPER CONTROL BOARD
1. INTRODUCTION
STOPPER is a control board dedicated to the movement of the chain barrier with 24Vdc motor.
The coexistance of various types of safeties such as the control of the absorbed power by the
motor and the velocity of the motor allows a rapid intervention of the anti - squeezing security
(sense).
Through the encoder present in the motor it is possible to control the exact position of the chain
and to use it without mechanical limit switches.
2. CONFIGURATION
Use this point to
connect the motor's casing
to the control panel and to
the ground.
Connector for the
battery charger ACG5482
3. ELECTRICAL CONNECTIONS
Terminal
1-2
Flasher output
Positive power supply for transmitter and receiver of the
3
photocell
4
Negative power supply for photocell transmitter
Negative power supply for photocell receiver and common
5
for commands and safeties
6
Limit switch of the chain raising
7
Limit switch of the chain lowering
8
STOP button input
9
RX photocell contact input
10
Pedestrian button input
11
Step by step button input
12
Not to use
13
Not to use
Example of connection
MOTOR CASING
CABLE CONNECTED
TO EARTH
Control board
to obtain a correct working of the accessories (photo devices in particular) connected
to the control board, it is very important that the entire system (motor + control
board) has only one mass reference system.
24 Vac
Motor/Encoder Connector
Function
Out: 24 Vac 25 W MAX
Out: +24 Vcc
150 mA MAX
Out: GND TX
Out: GND RX / Common
Normally closed (NC)
Normally closed (NC)
Normally closed (NC)
Normally closed (NC)
Normally open (NO)
Normally open (NO)
SCREWS FOR FIXING TO
must be bridged to the
THE ENGINE HOUSING
CONNECTION
CABLE
The control board has inputs for mechanical limit switches, for the step by step button, for the
pedestrian opening, for the safety photocells and the output for flashing light 24 Vac.
The unit also allows the regulation by trimmer both the automatic chain lifting and the motor
force.
Action can control motors at 24 - 30 Vcc with a maximum consumption of 7A.
Automatic
lifting of the
chain
Courtesy light
POWER
FUNC LIGHT
Courtesy light 24 Vac 25 W
Active during handling and for the following 3 minutes
Setting
Any contact which is
Normally Closed (N.C.)
common if not used.
You must therefore connect a small cable between the motor casing and the control box in
the point shown in the figure.
If there is a good ground connection it is advisable to connect all the system to it.
22
motor force adjustment
Buttons:
1 = YELLOW
2 = BLUE
3 = RED
Selector
MANUAL (Left)
AUTOMATIC (Right)
+ - -
Photocells
Power supply
150 mA MAX
Motor/ Encoder Connector.
Encoder +5 Vcc (brown)
Signal (green)
GND (white)
M
-

Publicité