INSTALLATION
All measures are expressed in milimeters unless otherwise indicated.
PRELIMINARY CONTROLS
• Control the stability and solidity of the zone where the columns are going to be fixed.
• Use an omnipolar interrupter with contact distance of at least 3 mm.
• The connection to the power supply must be separated from the connections to the
security and command devices.
INSTALLATION OF THE COLUMN (fig. 1, fig. 3, fig. 4)
1. Screw in the base for 1,5 - 2,0 cm the 4 screws M10x70 supplied.
2. Place than the base on the previously prepared base of cement (fig. 3).
3. The upper part of the base should be clean and perfectly horizontal.
4. Pass the plastic tubes of the cables through the central hole on the base and check again
the stability of the base.
5. Unscrew the 8 screws (10) and take off the frontal cover (8) and the rear cover (9) of the
column (fig. 4).
6. Place now the column structure on the base.
7. Fix now the column to the base with the 4 washers (5) and 4 nuts (4).
8. Fix the frontal covers (8) of both columns with 4 screws (10).
9. Now you can fix the chain to the rings on both columns respecting the level X in the middle
of the chain barrier as shown fig. 1.
HALF-YEARLY MAINTENANCE
1. Cut the power supply off and disconnect the batteries, if present. Clean and grease the
guide and the pignons internally.
2. Grease the internal transmitting chain (fig. 5).
3. Check the fixation nuts (fig. 6).
4. Control the electrical connections.
5. Supply the power again.
6. Check out the correct functioning of the obstacle recognition (encoder system).
7. Check out the correct functioning of all and of the security commands.
8. Replace any worn parts.
Description:
1 - Column
2 - Gearmotor with encoder
3 - Control board
4 - Autoblocking nut M10
5 - Washer 20x10
6 - Base plate
7 - Screw M10x70
8 - Frontal cover
9 - Rear cover
10 - Closing screw M5x10
INSTALLING THE PROTECTION SYSTEM
5
6
21
Screw TCEI M8X25 INOX
Spring D17 L13
Washer M12
G
B
4