OPERATION
To Turn the Laser On and Off (fig. 1)
With the laser off, place it on a flat surface. This model has three
ON/OFF buttons, one for a horizontal laser line (c), one for a vertical
laser line (d) and one for a side vertical laser line (e). Each laser line is
powered on by pressing its ON/OFF button. The laser lines can be
powered one at a time or at the same time. Pressing the ON/OFF
buttons again turns the laser lines off.
Using the Laser
The beams are level or plumb as long as the calibration has been
checked (see Field Calibration Check) and the laser beam is not
flashing (see Out of Tilt Range Indicator).
OUT OF TILT RANGE INDICATOR (FIG. 2)
The DW089 laser is designed to self-level. If the laser has been tilted
so much that it cannot level itself (average > 4° tilt), it will flash the laser
beam. The flashing beam indicates the tilt range has been exceeded
and IS NOT LEVEL (OR PLUMB) AND SHOULD NOT BE USED FOR
DETERMINING OR MARKING LEVEL (OR PLUMB). Try repositioning
the laser on a more level surface.
SLOPING THE LASER
If the DW089 laser is tilted beyond 15° out of level, its laser beams will
stay on longer between flashes to make it easier to do angled work.
USING THE PIVOT BRACKET (FIG. 1)
The DW089 laser has a magnetic pivot bracket (f) permanently attached
to the unit. This bracket allows the unit to be mounted to any upright
surface made of steel or iron. Common examples of suitable surfaces
include steel framing studs, steel door frames and structural steel
beams. The bracket also has a keyhole slot (g) allowing the unit to be
hung from a nail or screw on any kind of surface.
WARNING: Position the laser and/or wall mount on a
stable surface. Serious personal injury or damage to the
laser may result if the laser falls.