4.4. When the thermostat is working normally, a faint click can be heard when the load is switched on and
off.
4.5. Self diagnostics: when the floor sensor is used the thermostat detects if the sensor is missing or cut off
or if there is a short-circuit. The fault is indicated by blinking the red LED indicator B and blue LED indicator
C alternatively.
5.
User Instructions for Ensto Heat Control Application
With this application you can program and change the settings of your thermostat. Bluetooth technology
is used for the wireless connection. You can connect to one device at a time. The range in free space is
approximately 5m.
Commissioning
5.1. Download the Ensto Heat Control application from Apple Store or Google Play (figure 7).
5.2. Open the application. In the "DEMO" mode you can practice using the application. The Tutorial video
shows application's features and guides you through the commissioning. At any time, you can go back to the
Tutorial through the "Support" menu.
5.3. After the Tutorial, pair your mobile device with your thermostat (figure 8):
Remove the adjustment knob E (1).
Switch on the thermostat with the power switch A (2).
Press the Bluetooth button D on the thermostat for 1 second (3). The blue LED indicator C blinks (4).
When the application has found your thermostat, your mobile device displays the default name "New
thermostat" .
Press the "New thermostat" button within 45 seconds (5).
The blue LED indicator C turns off, when the pairing is completed or 45 seconds is exceeded.
Now you can find your thermostat in "Devices / My devices".
Put the adjustment knob E in place.
Operation Modes
5.4. Change the operation mode from the menu "Settings / Mode".
In "Floor" mode the thermostat adjusts the heating according to the floor temperature. Select the floor
setting temperature with the adjustment knob E.
In "Room" mode the thermostat adjusts the heating according to the room temperature, in which case
no floor sensor is needed. Select the room setting temperature with the adjustment knob E. When
measuring room temperature, the thermostat adjusts to the prevailing conditions in a few hours, after
which the precise operation starts.
In "Combination" mode the thermostat adjusts the heating according to the room temperature as well
as according to the minimum and maximum floor temperatures. Define for the floor material appropi-
ate minimum and maximum temperatures from "Settings / Floor temperature limits".
In "Power" mode the thermostat adjusts the heating without sensors according to power. Select the
length of the power cycle from "Settings / Power mode cycle time". Select the desired heating power
0 - 100% with the adjustment knob E.
5.5. If the floor temperature rises higher than the set temperature, the blue LED indicator C blinks four
times per minute as a warning and the load switches off until the floor temperature has dropped suffi-
ciently. This operation method is intended to protect sensitive floor materials such as parquet. Most parquet
manufacturers recommend the maximum temperature of floor covering approximately 27°C.
5.6. Note! The floor sensor only measures the concrete temperature. The floor covering material tempera-
tures are usually about 5°C lower than the concrete temperature, in which case the maximum limitation
temperature can be set at about +32°C. It is recommended to set the limitation as low as possible and raise
the value afterwards if needed. However, each flooring material is unique, so when an accurate temperature
limit is needed, the floor temperature must be checked with a separate thermometer.