Verify the presence of all components of the system
General visual inspection of the entire system
Control safety lever hook
Check cotter pin shackle
Cleaning and lubrification
Marking the presence of the instrument
Control of all the dimensions of the parts that make
up the system
Checking the wear of hooks, shackles and bells
Checking of the Load Cell
User
Specialized personnel
Form and structure of the shackle:
The shackles should be examined regularly by a qualified person. The time interval from one
check to another depends on how much the instrument is used, but it is recommended to not
exceed six months.
Therefore, one must:
- always inspect the shackle before use;
- carry out regular visual inspections to look for nicks, cracks, wear or damaged areas,
damaged threads on the pivot and body; if it is necessary, carry out a magnetic test or non-
destructive testing;
- the shackles which do not fully or partially satisfy the requirements, must be discarded.
Frequency of tests
Control
Daily
Weekly
13
Quarterly
Yearly