COMMISSIONING
COMMISSIONING
1. Fill the crankcase with engine oil. The recommended amount of oil for each model is indicated in the specification
chart.
2. Check oil level with an oil dipstick. It should be between the MIN and MAX marks on the oil dipstick.
3. Check fuel level.
4. Check the air filter for correct installation
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:
1. During commissioning, do not connect power consumers, the power of which exceeds 50% of the nominal (operating)
power of the device.
2. After the first 20 operating hours, be sure to change the oil. It is better to drain oil while the engine is still hot after
operation to ensure quick and complete oil draining.
3. Check and clean the air filter, fuel filter and spark plug.
ENGINE START
ENGINE START
IMPORTANT!
IMPORTANT!
IMPORTANT!
1. Check oil level.
2. Check fuel level.
3. Open the vent on the fuel cap to the
"ON" position (fig. 1).
4. Turn the air choke control knob to the "START"
position (fig. 2).
5. Pull the manual starter until a slight resistance is felt, then pull it
toward you relatively sharply. Slowly turn the manual starter by hand,
do not release it abruptly.
6. Turn the air choke control knob to the "RUN" position.
IMPORTANT!
- Before connecting the load, allow the engine to run for 1-2 minutes to warm it up.
- When disconnecting the load after lengthy operation, do not turn off the generator. Allow the generator
to run idle for 1-2 minutes so that it cools down.
ATTENTION – DANGER!
In the power supply mode, the generator should operate no longer
than 1 minute in the range from nominal to maximum power.
Useful tip: If the engine stalls or does not start, turn the engine
switch to the "ON" position, and then pull the manual starter. If
the oil level indicator flickers for several seconds, add oil and restart
the engine.
Each time you start the generator, be sure to check oil and fuel level.
Before starting the generator, connect the ground wire to the ground
terminal.
Useful tip: to ensure long-term operation of the generator engine, it
is important to observe the following tips:
Do not connect two or more devices at a time. The start-up of many
devices requires high power. Devices should be connected one at
a time according to their power rating. Do not connect any power
consumers within the first 2 minutes after the generator has been
started.