CARE AND CLEANING
Handle measuring instruments with care. Clean with soft cloth only after any use. If necessary damp
the cloth with some water. If the instrument is wet clean and dry it carefully. Pack it up only if it is per-
fectly dry. Transport in original container / case only.
INTENDED USE OF INSTRUMENT
The instrument emits a visible laser beam in order to carry out the following measuring tasks:
Setting up plumbing points.
EXCEPTIONS FROM RESPONSIBILITY
1.
The user of this product is expected to follow the instructions given in the user manual. Although
all instruments left our warehouse in perfect condition and adjustment the user is expected to
carry out periodic checks of the product's accuracy and general performance.
2.
The manufacturer, or its representatives, assumes no responsibility of results of a faulty or
intentional usage or misuse including any direct, indirect, consequential damage, and loss of
profits.
3.
The manufacturer, or its representatives, assumes no responsibility for consequential damage,
and loss of profits by any disaster (earthquake, storm, flood etc.), fire, accident, or an act of a third
party and/or a usage in other than usual conditions.
4.
The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of
profits due to a change of data, loss of data and interruption of business etc., caused by using the
product or an unusable product.
5.
The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of
profits caused by usage other than explained in the user manual.
6.
The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong
movement or action due to connecting with other products.
LASER CLASSIFICATION
The instrument is a laser class 2 laser product according to DIN IEC 60825-1:2014.
It is allowed to use the unit without further safety precautions.
The eye protection is normally secured by aversion responses and the blink reflex.
The laser instrument is marked with class 2 warning labels.
Please note:
If you return instruments for repair / for adjustment to us please disconnect batteries or rechargeable batteries
from the instrument - this is for safety reasons!
Thank you.
EN
www.geo-fennel.de
GE RMA NY
Laser
2
IEC 60825-1:2014
P ≤ 1 mW @ 635 - 670 nm
www.geo-fennel.de
GE RMA NY
Laser
2
IEC 60825-1:2014
P ≤ 1 mW @ 515 - 530 nm