- Turn the handle of the drain valve clockwise. The
drain is completely open when the handle is in the
vertical position. If you need to empty the
container several times.
GAS FRYERS SIMPLE
BURNER IGNITION AND EXTINCTION
The gas valve control knob has the following
positions:
OFF
PILOT IGNITION
MINIMUM TEMPERATURE
INTERMEDIATE TEMPERATURES
MAXIMUM WATER TEMPERATURE
PILOT IGNITION
-
Turn the knob to position " pilot on " .
- Press the push button " pilot on " right down and,
holding it pressed, press the piezoelectric lighter
push button at the same time. The pilot flame
lights automatically.
- Check that the flame is lit through the holes on the
appliance panel.
- Keep the valve push button pressed for 10-15
seconds to heat the thermocouple and then let it
go.
- Repeat this operation if the burner goes out.
MAIN BURNER IGNITION
- Turn the knob to the chosen temperature setting
for cooking.
TURNING OFF
- To switch the main burner off, turn the knob to
position " pilot on " .
- To turn off the pilot push the button " off " , then
release it.
GAS FRYERS POWER
BURNER IGNITION AND EXTINCTION
The gas valve control knob has the following
positions:
OFF
PILOT IGNITION
MINIMUM TEMPERATURE
INTERMEDIATE TEMPERATURES
MAXIMUM WATER TEMPERATURE
PILOT IGNITION
- Turn the knob to position " pilot on " .
- Press the push button " pilot on " right down and,
holding it pressed, press the piezoelectric lighter
push button at the same time. The pilot flame
lights automatically.
22