Operation; Short Form Instructions (Setup); Communication - Endress+Hauser iTEMP PCP TMT 181 Mise En Service

Masquer les pouces Voir aussi pour iTEMP PCP TMT 181:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operation

Communication

6 Operation

6.1 Short form instructions (SETUP)

Standard settings
(Quick-SETUP)
Expanded settings
Service functions
6.2 Communication
The head transmitter must be set up using a PC and configuration set. The following
points must be taken into account if trouble free setting up is to be achieved:
• Configuration software installation
• Connect the head transmitter to the PC using the connection cable from the
configuration set
Configuration software installation
System conditions
Recommended minimum
configuration
Installation start
Connecting the head transmitter to the PC using the configuration kit
connection cable
1. Connect the SETUP connector of the interface cable to the SETUP socket in the
head transmitter (see chapter 5.2 Connecting measurement unit).
2. Connect the RS232C connector to a free serial interface socket on the PC. In order
to achieve optimum connection tighten the RS232C connector screws to the PC.
Hint:
Configuration of the head transmitter can be done either under power e.g. using
a 9 Volt battery or in an installed condition during measurement operation.
[1] 2-, 3-, or 4-wire connection
[2] on TC-connection
[3] on 2-wire connection
Presettable parameters
- Sensor type (see Chap. 11 Techn. data)
[1]
- Connection mode
- Units (°C/°F)
- Measurement range start (see Chap. 11 Techn. data)
- Measurement range end (see Chap. 11 Techn. data)
- Cold junction compensation (internal/external)
- Compensation resistance (0...20 Ω)
- Fault condition reaction (see Chap. 11 Techn. data)
- Output (analogue standard/inverse)
- Damping (0...60 s)
- Offset (-9.9 to +9.9 K)
- Measurement point identification/TAG
- Simulation (on/off)
- IBM PC or compatible computer (min. Pentium 166 MHz)
- Windows 95/98/ME/NT4.0/2000
- 64 MB RAM
- min. 30 MB free memory on hard drive
- CD-ROM drive
- Screen resolution 800 x 600 Pixel
- free serial interface
- Pentium 400 MHz
- 128 MB main RAM
- 120 MB free hard drive memory
- Screen resolution 1024 x 768 Pixel
Start Windows
1. Place installations-CD in the respective drive
2. Start "Setup.exe" and follow the installation instructions
3. If required the help/operating manual can be printed out once the
software has been successfully installed.
Operation
[2]
[3]
27

Publicité

Table des Matières
loading

Table des Matières