Télécharger Imprimer la page

Hama 00076044 Mode D'emploi page 7

Publicité

Les langues disponibles

Les langues disponibles

Activating and deactivating the daily alarms
To activate or deactivate the daily alarms, briefly press
the "+" button.
Press 1x: Alarm 1 activated
Press 2x: Alarm 2 activated
Press 3x: Both alarms activated
Press 4x: Both alarms deactivated
Information:
• After eight seconds without a button being pressed,
the clock switches automatically from Setting mode to
normal clock mode.
• The alarm will sound for two minutes if you do not
deactivate it by pressing any button. In this case, the
alarm will be repeated automatically after 24 hours.
Automatic snooze function
• Proceed as follows to activate the automatic snooze
function:
• While the alarm is sounding, press the "Snooze/Light"
button to activate the snooze function. When the
snooze function is active, the "Zz" symbol appears in
the display.
• This operation moves the alarm back by five minutes
and the alarm will restart at this time.
• Pressing any button can interrupt the snooze function.
(except History, Alert, Channel, Memory,
"
/Hpa-inhg &
/°C/°F")+
Setting the temperature alarm
• Press and hold down the "Alert" button for three
seconds until the symbol for the temperature alarm
stars to flash.
• Press the "Channel" button to switch between the
different radio channels (CH1, CH2, CH3) (for multiple
sensors within range).
• Press "Alert" to confirm the selected channel.
• The symbol
for the upper limit of the temperature
alarm starts to flash. Use the arrow keys
"
/Hpa-inhg &
/°C/°F" to set the required
maximum temperature.
• Press "Alert" to confirm your setting.
• The symbol
for the lower limit of the temperature
alarm starts to flash. Use the arrow keys "
/Hpa-inhg
&
/°C/°F" to set the required minimum temperature.
• Press "Alert" to confirm your setting and to end the
setting procedure.
Activating and deactivating the temperature alarm
• Briefly press the "Alert" button to activate or
12
deactivate the temperature alarm for all the channels
of the outdoor sensors.
• Alarm activated: Temperature alarm symbol appears in
display
• Alarm deactivated: temperature alarm symbol
disappears
Information:
• You can set up a temperature alarm for every channel.
• If you set the maximum to a temperature that is lower
than the minimum, then you will not be able to
complete the setting process.
• The minimum must always be at least 1°C below the
maximum.
• When the temperature alarm sounds, the appropriate
channel and the upper or lower limit symbol is shown.
Moon Phase Display
A B C D E F G H
The Moon Phase of each day is shown on the LCD.
A: New Moon
B: Waxing Crescent
C: First Quarter
D: Waxing Gibbous
E: Full Moon
F: Waning Gibbous
G: Last Quarter
H: Waning Crescent
Summer time display
The summer time is displayed by the "S" symbol in the
display. The clock works this out using the DCF signal.
°C/°F temperature display
The temperature is displayed either in °C or °F. Briefly
pressing the "
/°C/°F" button allows you to switch
between the individual modes.
Temperature trend display
After you inset the batteries, the weather station
measures the current temperature. The trend display
shows a neutral temperature course (horizontal arrow).
The further course of the trend display is determined as
follows:
• If, after an hour, the temperature is more than 1 °C
higher than the value measured first, then a positive
course is displayed (arrow pointing upwards).
• If, after an hour, the temperature is more than 1 °C
lower than the value measured first, then a negative
course is displayed (arrow pointing downwards).
If the temperature does not change within an hour,
then the upward or downward pointing arrow becomes
a horizontal arrow.
The measured temperature is then taken as then neutral
value from which further prognoses are made.
Maximum / Minimum Temperature / relative Humidity
• Briefly press the "Memory" button to display the
maximum / minimum temperature and relative humidity.
After five seconds, the display switches back to the
normal time display mode.
• Pressing and holding down the "Memory" button for
3 seconds allows you to delete the saved maximum
and minimum temperature and relative humidity.
Relative humidity trend display
After you insert the batteries, the weather station
measures the current relative humidity. The trend display
shows a neutral relative humidity course (horizontal
arrow).
The further course of the trend display is determined as
follows:
• If, after an hour, the relative humidity is more than
5% higher than the value measured first, then a
positive course is displayed (arrow pointing upwards).
• If, after an hour, the relative humidity is more than
5% lower than the value measured first, then a
negative course is displayed (arrow pointing
downwards).
If the relative humidity does not change within an hour,
then the upward or downward pointing arrow becomes a
horizontal arrow. The measured relative humidity is then
taken as the neutral value from which further prognoses
are made.
Air pressure display
The course of the air pressure within the last twelve
hours is displayed on the display in the form of a bar
chart. In addition, you have the option of displaying the
exact air pressure value, for example, 3 hours previously,
in the normal air pressure display. To do this, proceed as
follows:
Press the "History" button briefly to display the air
pressure values of the last few hours. For example,
pressing the button seven times displays the air
pressure value seven hours ago.
You have the option of displaying the air pressure in
mb/hpa or inHg. To switch between these displays, briefly
press the "
/Hpa-inhg" button.
Weather forecast
The weather station uses the air pressure data of the last
six hours to create a weather forecast the next 12 to 24
hours. It must be taken into account that the data within
the first twelve hours after inserting the batteries will not
be correct, as the weather station has to get used to the
environmental circumstances after the restart.
The forecast can be given for a radius of up to 15-20km.
When forecasting the weather, the station uses five
different symbols: sunny, partly cloudy, cloudy, rainy and
stormy.
In addition, a snowflake is displayed when the outdoor
area temperature drops below minus four degrees.
Location / tides display /moon phase /sunrise and sunset
display
• Press and hold down the "Location" button for three
seconds until the city selection begins to flash. Use the
arrow keys "+ & -/wave" to set your location. You can
see the list of all cities on the next page.
• Press "Location" to confirm your setting.
The weather station now uses the saved data on the
selected city to determine the sunrise and sunset
times, the strength of the tides and the phases of the
sun and the moon.
Germany
City
Abbreviations
Aachen
AC
Berlin
B
Düsseldorf
D
Dresden
DD
Erfurt
EF
Frankfurt
F
Flensburg
FL
Freiburg
FR
Hannover
H
Bremen
HB
Hamburg
HH
Rostock
HRO
Stralsund
HST
Köln
K
Kiel
KI
Kassel
KS
Leipzig
L
München
M
Magdeburg
MD
Nürnberg
N
Regensburg
R
Stuttgart
S
13

Publicité

loading