Logic
Definition
Configuration of
AUX 3 output.
AUX 3
26-27*
* If you use AUX3 as the second radio channel, the outlet must be configured as second radio channel but the transmitter must be stored in the coupling receiver. If you use
AUX3 with any function other than the second radio channel, no transmitter must be stored as second radio channel in the coupling receiver.
Protection
Setting the
protection level
level
Serial mode
(Identifies how board
SERIAL MODE
is configured in a BFT
network connection).
Address
ADDRESS
Configuration of
EXPI1 input on
input-output expan-
EXPI1
sion board.
Configuration of
EXPI2 input
on input-output
EXPI2
expansion board.
26 -
SP 3500 - SP 3500 SF
INSTALLATION MANUAL
Cross
out
Default
setting
used
0
1
2
3
4
5
0
6
7
8
9
10
0
1
2
0
3
4
0
1
2
3
[ ___ ]
0
0
1
2
3
4
5
6
7
8
9
10
11
12
1
1-2
13
14
15
16
17
18
0
1
2
3
4
5
6
0
7
1-3
8
9
10
11
12
Output configured as 2nd Radio Channel.
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light
Output configured as Alarm
Output configured as Flashing light
Output configured as Latch
Output configured as Magnetic lock
Output configured as Maintenance
Output configured as Flashing Light and Maintenance.
A - The password is not required to access the programming menus
E - The board's parameters can be edited via the U-link network
Not used
Not used
Not used
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
E - The option of editing the board's parameters via the U-link network is disabled.
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other
boards.
SLAVE opposite leaves in local network : the control unit is the slave in an opposite leaves network
with no smart module (fig.R)
MASTER opposite leaves in local network: the control unit is the master in an opposite leaves net-
work with no smart module (fig.R)
Identifies board address from 0 to
119
(see U-LINK OPTIONAL MODULES section)
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing
the movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening
the movement stops.
Input configured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board
is switched automatically to safety device test input, EXPFAULT1.
Input configured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2)
on input/output expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on
input/output expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is
switched automatically to safety device test input, EXPFAULT1.
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while
closing the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically
to safety device test input, EXPFAULT1.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while ope-
ning the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically
to safety device test input, EXPFAULT1.
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing
the movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening
the movement stops.