axhess ProfiPower 2.940.006 Mode D'emploi page 18

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

8
error discarding
Problem
When used as
Connected device does
a mobile po-
not come into operation.
wer source.
When carrying the Power
GB
Station, time indication
jumps to 12:00 o'clock.
Housing of the device
does not make a correct
connection with the base
plate.
No read-out in the
LCD-display of the Power
Station.
When used
The vehicle with a weak
as a booster
battery does not start,
stage.
despite the connection
with the booster cables.
When using
Lamp doesn't reproduce
the inspection
any functions.
light.
30
Cause
Solution
12 V exit of the Power
Press the »START/BOOST«
Station is not activated.
key. Switch on connected
device.
Non-correct connection
Place housing again and
to the battery.
tighten levelling screws
completely. There may not
be any lash to the screws.
Battery does not
Turn housing 180 ° and
correspond to the contact
place on the battery. Do
points of the Power
not use any force! Battery
Station.
needs to turn 180 ° on the
base plate.
Lateral bottom brackets
Fold out base plate
are in the way.
support until fastening
finds place.
Empty battery.
Charge battery or replace
Battery does not make
by a completely charged
contact with the Power
battery. Check mould and
Station.
contact of the battery.
Without using any force,
place housing correctly
over the battery.
Tighten levelling screws.
Make sure to tighten com-
pletely!
The »START/BOOST«
Press the »START/BOOST«
function is not activated.
key twice.
Sparking of the vehicle has
Start sparking.
not been started.
The receiving battery
Interrupt booster stage,
is discharged too far or
replace battery of the
unusable.
vehicle.
The Power Station is not
Charge Power Station or
completely charged.
place a charged battery in
the Power Station.
Crocodile clips of the
Check connections.
booster cable are not
connected correctly.
12 V plug not connected
Check connection,
correctly to the Power
possibly rectify.
Station.
12 V output of the Power
Press the »START/BOOST«
Station is not being
key once, »VOLTAGE OUT«
activated.
lights up. Switch on-key
of the lamp is activated,
enlightens red. Press the
switch on-key. For swit-
ching off, press again.
Fuse of the 12 V-plug has
open 12 V plug, change
blown. Illumination of the
fuse. Close plug again.
switch on-key is not active.
9
warranty
The provided warranty refers exclusively to manufacturing and material defects. We provide a 24 months
warranty ever since the date of purchase. In case you want to claim your warranty, please send a short
description of the complaint/failure and your buying voucher (receipt) together wiht the device. For further
completion, return the device with the above mentioned appendixes to your seller. Without a buying
voucher and a clear description of the complaint, warranty can not be completed.
This warranty obligation is being given based on private use. This device is not developed for professional
use.
The battery does not form part of the warranty because it concerns a waste product.
Take care of the battery in conformity with the measures described in this manual, well charged
batteries live longer.
10 removal *
Act environmentally aware when removing electric devices/batteries!
Protect our environment!
10.1 removal packaging
Deposit packaging material with according recyclable domestic refuse.
All packaging material is recyclable.
10.2 removal device and accessories
If one day the Power Station should be taken out of operation, ascertain yourself of the valid removal re-
quirements at your responsible disposer and/or your local agency. Hand over the device and its
accessories to your seller or bring it to a suitable public trash collecting point.
Remove the battery before you remove the device!
10.3 Battery removal
Before you remove the device once and for all, unconditionaly first remove the battery!
This device is developed in such a way it enables a simple and uncomplicated removal of the battery from
the device.
This battery contains toxic substances. Never dismantle the battery or break into pieces.
Batteries NEED to be removed to a collecting point. At these points old batteries are picked up on request
by several trash disposers.
Batteries are being removed separately and have their own specific cycle. Defective, old or weak batteries
do not belong to the domestic refuse! Return defective, old batteries to your seller or to an appropriate
collecting point. In case of doubt turn to your responsible disposer/local agency. Wrap the battery poles
with isolation tape before removing the battery.
Also at battery removal: always consider the safety references!
* The manufacturer has, in accordance with the valid requirements, paid in advance the disposal fees to
the right organizations for as well the packaging, the device and the battery.
GB
31

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour axhess ProfiPower 2.940.006

Table des Matières