1-5. INSTALLATION DIAGRAM
Open as a rule
More than 19-11/16 in.
(5 00 mm) if the front and
both sides are open
More than
3-15/16 in.
e n
(100 mm)
Open as a rule
More than 19-11/16 in. (500 mm)
if the back, both sides and top
are open
6-7/8
Air inlet
2 - (15/32 × 1-13/32)
oval holes (Base bolt M10)
3
More than 13-25/32 in.
(350 mm)
Outdoor unit installation
37-13/32
2-U-shape notched holes
(Base bolt M10)
23-5/8
Air inlet
Air outlet
After the leak test, apply insulat-
ing material tightl y so that there
is no gap.
When the piping is to be attached to
a w all containing metals (tin plated)
or metal netting, use a chemically
treated ooden piece 25/32 in. (20
mm) or thicker bet een the all
and the piping or rap 7 to 8 turns
of insulation vinyl tape around
the piping.
To use existing piping, perform
COOL operation for 30 minutes
and pump do n before removing
the old air conditioner. Remake flare
according to the dimension for new
refrigerant.
More than 3-15/16 in. (100 mm)
More than 7-7/8 in. (200 mm) if there
are obstacles to both sides
Units should be installed by licensed contractor according to
local code requirements.
17 5
Air inlet
2 - 12 × 36
oval holes (Base bolt M10)
Unit : inch
PARTS TO BE PROVIDED AT OUR SITE
(A) Pow er supply cord*
(B) Indoor/outdoor unit connecting ire*
(C) Extension pipe
(D) Wall hole cover
(E) Piping tape
Extension drain hose (or soft PVC
hose, 19/32 in. (15 mm) inner
(F)
diameter or hard PVC pipe VP16)
(G) Refrigeration oil
(H) Putty
(I) Pipe fixing band
(J) Fixing screw for (I)
( ) Wall hole sleeve
Soft PVC hose, 19/32 in. (15 mm)
inner diameter or hard PVC pipe
(L)
VP16 for drain socket (1)
* N o t e :
Place indoor/outdoor unit connecting ire (B) and
po er supply cord (A) at least 3 ft. (1 m) a ay from
the TV antenna ire.
The " 'ty" for (B) to ( ) in the above table is quantity
to be used per indoor unit.
Outdoor unit installation
2-U-shape notched holes
95 0
(Base bolt M10)
600
Air inlet
Air outlet
1
1
1
1
1
1
Little
amount
1
2 to 7
2 to 7
1
1
Unit : mm