Water Leakage Test

The final test after loading the camera is explained below. Always perform this test. It can be performed
easily in a water tank or a bathtub. The required time is about five minutes.
• At first, immerse the Case for only three seconds and check that no water drop etc. to the Case.
• Next, immerse the Case for 30 seconds and check that no water drop etc. to the Case.
• Furthermore, immerse the Case for three minutes.
• Check followings:
- check that no water has accumulated the Case.
- check that the Case is not clouded.
- check that no water has entered the Case.
• If inside of the Case becomes cloudy or there is a water drop, do the maintenance of the O-ring and
perform the water leakage test again.