1. Select a suitable mounting location and verify there is sufficient cable to connect
with cables from the housing.
2. Mark and drill mounting holes in the surface using the ceiling mount bracket.
3. Pull out cables required to connect to the dome camera from the ceiling.
4. Attach the ceiling mount bracket using plastic anchors and screws.
5. Attach 1.5 inch adapter to the pipe and fix it using set screw of the adapter.
6. Pull out camera cables through the pipe and attach the camera to adapter and fix
them using set screw of the adapter.
7. Attach the safety wire to the pipe to one of M6x35 screws of the ceiling mount
bracket.
8. Join every connectors and organize cables
9. Lock hexagonal nut of the ceiling mount bracket to fix camera attached pipe and
ceiling mount bracket.
Basic Configuration of Camera System
No.
Connector
1
Power Jack
2
RJ-45
3
RCA
4
RCA
5
5-pin Cable
6
2-pin Cable
Wire Color
BLACK
BLACK
BLACK
GRAY
YELLOW
WHITE
VIOLET
BROWN
GRAY
RED
BLACK
Description
Camera Power
Ethernet, RJ-45 port compatible with 10/100Mbps
Audio Input
Audio Output
Alarm Input 1
Alarm Input 2
Alarm Input 3
Alarm Input 4
GND
Alarm Out
GND