Side clearance requirements
The models shown are with the included island trim. A
low backguard option is available (purchased
separately).
For an island trim install, counter surface should have
a cantilever edge meeting the back section of the
island trim.
If an inner wall is used under the cantilever counter
top there should be a 1/8'' (3 mm) gap from the rear
of the range.
Shaded area behind range indicates minimum
clearance to combustible surfaces. Combustible
materials cannot be located within this area with the
Island Trim.
Pro Harmony side clearances
inches (mm)
6" (152)
6" (152)
6" (152)
28" (711)
23 ⅞" (606)
44 ⅞" (1,140)
There is a 44-7/8'' (1,140 mm) total clearance.
There is a 23-7/8'' (606 mm) maximum recess depth.
9
30" (762) –
36" (914)
36 ¾" (933) –
35 ⅞" (911)
Pro Grand side clearance
inches (mm)
6" (152)
6" (152)
6" (152)
28" (711)
25⅛" (638)
There is a 48-3/4'' (1,238 mm) total clearance.
There is a 25-1/8'' (638 mm) maximum recess depth.
30" (762) –
36" (914)
35⅞" (911) –
36¾" (933)
48¾" (1238)