Nice HSRE12 Instructions Pour L'installation page 7

Masquer les pouces Voir aussi pour HSRE12:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
Type
Led in programming
1
Slow flash
2
Quick flash
3
Always lit
Note – in the case of devices that send ON-OFF commands, the relay output is always bistable (Off-On); in this case type 2
or type 3 are the same.
Dip
Switch
TO POSITIVE (+ 12 Vcc)
OFF
Receiver is ON
1
ON
Receiver is OFF
2
OFF
Alarm memory disabled
ON
Alarm memory visible via leds, with receiver OFF and is reset on subsequent reactivation.
3
OFF
The buzzer is disabled (alternatively the volume can be adjusted by means of the specific trimmer).
ON
The buzzer is active
4
OFF
The relays only switch to ON
ON
In the event of an alarm, relays 1 - 12 also switch when the receiver is OFF
5
OFF
Relay 12 only activates according to the detectors memorised on output 12.
ON
In the event of any alarm, relay 12 opens for 2 s (alarm OR function)
6
Not used
Table 2: output functions
Output contact response
Closed, opens for 2 s in event of alarm
Open, closes for 2 s in event of alarm
Open, closes for 180 s in event of alarm
Table 3: Dip switch operation
Operation
RESET input connection
OPEN
Receiver is ON
Receiver is ON
TO NEGATIVE (- GND)
Receiver is OFF
Receiver is ON
English - 5