Milwaukee HEAVY DUTY M12 3PL Notice Originale page 13

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
3
CHECKING THE LEVEL ACCURACY OF THE VERTICAL
PLANE
1. Hang an approximately 4 m plumb
line on a wall.
2. After the plumb line has settled, mark
point a1 on the wall, behind the
plumb line, near the plumb cone.
3. Set up the laser on a tripod or on a
fl at surface in front of the wall at a
distance of approximately 2 m.
4. Switch ON the self-leveling mode,
and press the button to project the
vertical beam towards the plumb line.
5. Turn the laser so that the vertical
plane will merge with the plumb line
below the hanging point.
6. Mark point a2 on the wall, in the
middle of the vertical plane at the
same height as a1.
7. The distance between a1 and a2,
should be no more than 1 mm.
ENGLISH
a1
a2
a1
13