6. Align the top of the wood bracket along the horizontal
line drawn in Step 2. Align the centerlines of the
bracket and cooktop.
7. Drill a 3'' (76 mm) deep 3/16'' (3 mm) tap hole through
the wooden bracket, wall, and into the stud.
8. Use three, 3'' (76 mm) screws to attach the bracket to
the wall, as shown in Figure 9. For support of the hood,
use three studs. Countersink the screw heads to
prevent interference with the hood.
9. On the wood bracket, mark the locations used to hang
the hood according to Figure 10.
28" (713)
28" (713)
28" (713)
10. Drill a 3/16'' (4.8 mm) tap hole through the wooden
bracket and wall. These 5/8'' (16 mm) screws do not
need to go into the studs.
11. Use (2) 5/8'' (16 mm) screws to secure the wood
¼
bracket leaving
'' (6 mm) of each screw exposed for
hanging the hood.
Vertical discharge ceiling cutout
VERTICAL DISCHARGE installations require a cutout in
the ceiling to accommodate 10'' (254 mm) duct and 5/8''
(16 mm) diameter clearance hole for ½'' (12.7 mm) conduit
to the j-box (Figure 11).
inches (mm)
30" (762)
30" (762)
30" (762)
Figure 11: Vertical Ceiling Cutout Dimensions
Installation Instructions
2 x 1½" (38)
2" (51)
28" (713)
28" (713)
28" (713)
inches (mm)
Figure 10: Hanging the Hood
6" (152)
6" (152)
6" (152)
Conduit
Conduit
Conduit
Zone
Zone
Zone
12" (305)
12" (305)
12" (305)
Horizontal discharge wall cutout
HORIZONTAL DISCHARGE installations require a wall
cutout, as shown in Figure 12, to provide clearance for the
transition. The location of the cutout is determined by the
hood installation height.
Back Wall
30" (762)
30" (762)
30" (762)
30"– 40" (762 –1016) from cooking surface.
30"– 40" (762 –1016) from cooking surface.
30"– 40" (762 –1016) from cooking surface.
inches (mm)
Figure 12: Horizontal Wall Cutout Dimensions
Prepare for the wire routing
12. Remove junction box channel covering the wires
(Figure 13, "A").
13. Remove circular knockouts behind junction box
channel (Figure 13, "B").
"B"
Electric
Conduit
12" (305)
12" (305)
12" (305)
Zone
12"
(305)
7" (178)
7" (178)
7" (178)
Hood mounting heights
Hood mounting heights
Hood mounting heights
"A"
Figure 13: Junction Box Channel