SFA SANICUBIC 1 Instructions D'installation Et D'entretien page 7

Masquer les pouces Voir aussi pour SANICUBIC 1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTRUCTIONS ONLY FOR QUALIFIED PROFESSIONAL SPECIALISTS
15
WORK THAT MAY BE REQUIRED
ELECTRICAL INSTALLATION MUST BE CARRIED
OUT BY A PROFESSIONAL ELECTRICIAN
Before carrying out any other types of work, disconnect the Sanicubic
from the power supply.
UNIT ALARM
Possible preliminary maintenance operations on the unit
PROBLEM
PROBABLE CAUSES
No motor starts and the
No power
power yellow LED is off (*)
The LED warning light is on
1 – Obstructed pump
2 – Blocked up pump
The LED flashing warning
Faulty detection system
light
Possible secondary maintenance operations
PROBLEM
PROBABLE CAUSES
The motor does not start
1 – Faulty electronic card
but override works
2 – Faulty detection system
Pump running continuously
1 – Obstructed discharge pipe
2 – Pump discharge height
too high
3 – Faulty electronic card
Pump starting up
1 – The non-return valve is
intermittently
leaking or broken
(*) A flashing yellow LED indicates that there has been a power cut.
(**) Warning: if pumping height is high, 90° elbows should be avoided.
16
1
®
The unit beeps to show that it
is no longer under power.
SOLUTIONS
Check your electrical
connections
Press the override button
continuously to get the
pumps working
Contact Saniflo after sales
16
1
service
Unclip the cover.
Unscrew the metal clamp
on the motor (the check valve
SOLUTIONS
stays in place while the motor
is being repaired).
1 – Contact Saniflo after-sales
service
1 – Remove obstruction from
the discharge pipe
2 – Check installation (**)
3 – Contact Saniflo after-sales
service
1 – Clean or change the valve
16
2
Unscrew the metal clamp
Remove the motor power
wires
connector.
16
3
Remove the screws
the inspection cover.
Use the handle
motor carefully.
DISMANTLING
INSTRUCTIONS RESERVED EXCLUSIVELY FOR
QUALIFIED PROFESSIONAL SPECIALISTS
DISCONNECT THE UNIT FROM
POWER SUPPLY (the green indicator
light must be off).
A
A
B
C
.
B
from the screw
C
D
E
from
D
to lift the
E
F
16
4
If the faulty motor has to be
sent back to the manufacturer
remove screws
from the
F
inspection cover.
INSTALLING A MOTOR
Remove the plug and the
inspection cover.
Screw the motor onto the
inspection cover and put the
cover back in place.
Reconnect the motor power
wires (cf. illustration ).
Warning:
Comply carefully with the
color code:
Blue wire with the blue wire
Brown wire with the brown
wire
Green wire with the green
wire
White wire with the white wire
Connect the unit to the power
supply.
Carry out a complete test for
commissioning.