Minimum Clearance To Combustible Enclosures - Napoleon STARfire Serie Mode D'emploi

Masquer les pouces Voir aussi pour STARfire Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.2

minimum clearance to combustible enclosures

WARNING
!
Risk of fi re!
The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite,
etc. provided that these materials do not cover the appliance opening.
important:
The HDX35 requires a minimum inside enclosure height of 70" (1778mm), measured from the bottom of the ap-
pliance. For temperature requirements, this area must be left unobstructed. It is recommended that the enclo-
sure be ventilated at the top and bottom to circulate the air.
NOTE: JOINT COMPOUNDS AND TAPES
THAT ARE RESILIENT TO HEAT AND
CRACKING SHOULD BE USED WHEN
TAPING AND MUDDING SEAMS.
37 1/4"
946mm
MINIMUM
70"
1778mm
MINIMUM
ENCLOSURE
HEIGHT
TOP OF
FIREPLACE
OPENING
32 3/4"
832mm
MINIMUM
COMBUSTIBLE
MATERIAL
STEEL STUD
FRAMING
SAFETY BARRIER
NON-COMBUSTIBLE
MATERIAL
TOP OF ENCLOSURE
INSULATED
SLEEVE
framing
BRICK
2" 51mm
0" (0mm) IF NON-
COMBUSTIBLE FINISHING
IS USED SUCH AS BRICK
AND STONE
1"
25mm
52 7/16"
1332mm
MINIMUM
PLUS RISE *
W415-2372 / A / 11.14.19
EN
27