Fig. 6 :
Lock interface
1836S00
EN
44
Note!
Protection rating IP 30 must be achieved: Distribution boxes (Fig. 2 page 41)
which achieve a minimum protection rating of IP 30 must be used for the installation.
1
A
B
C
D
E
F
1
Screw-type terminal strip
A
Locking +
B
Locking –
C
V
+
B
D
Locked message (via
armature monitoring contact AKRR)
E
GND
F
Door contact (via
monitoring contact RR)
3
Jumpers, if severed, safety functions are
switched off
("Configuring safety functions / severing jumpers", page 43)
J1
The local Emergency Open function can be deactivated
from the central location (Tab. 3)
Switch off C-Conformity
J2
J3
Release delay is activated
4
1
Hi-O terminating resistor
2
Hi-O group switch, must be set to Off position
3
2
4
3
2
1
4
ge
rt
2
gn
Screw-type terminal strip
1
CAN_H
2
CAN_L
3
V
+
B
4
GND