Configuring safet y functions / severing jumpers
With the Lock interface 1386S00 (Fig. 5), safety functions are switched off by
severing jumpers on the circuit board. There are two separate jumpers which
form a jumper pair for each safety function. Both jumpers in a jumper pair must
always have the save status.
Attention!
Property damage due to the severing of a jumper with electrical current
switched on: The Lock interface 1386S00 must be de-energised prior to the
severing of a jumper.
Jumper pairs
J1a / J1b J2a / J2b J3a / J3b
The adjusted safety functions still have to be activated during the commissioning
(separate Anleitung D01022xx ePED
1
Only possible in combination with the Central control unit 1386CMC.
1
Refer to Tab. 3 to determine which
jumpers must be severed in order
to switch on or reverse safety
functions.
2
Sever the jumpers by making two
cuts in one segment to ensure that
the contact has been disconnect-
ed.
Central station
1
can deactivate
Conformity
local
Emergency open
Yes
Yes
®
Escape Door Terminal 1836–00).
C-
maximum
Release
delay
Yes
keine
t
1 s . . . 15 s
1
Yes
t
1 s . . . 180 s
2
t
1 s . . . 15 s
1
Yes
t
1 s . . . 180 s
2
t
1 s . . . 120 s
1
No
t
1 s . . . 300 s
2
t
1 s . . . 120 s
1
No
t
1 s . . . 300 s
2
EN
1
1
1
1
43