Welding
20
How to adjust your welding set (see figure 2 page 14)
On the welding scale :
— set the pointer of potentiometer P3 opposite the thickness to be
weided.
— according to the dia. of the wire, read in the corresponding section the
?imber inarked opposite the pointer
— set the number read on the switch CM1 (see photo page 3)
— select the welding inethod CM2
— WELD
— fine clown the adjustment by actuating P3
So as to avoid die electrode wire sticking in the welding bath when spot
welding, an anti-sticking device or end of welding programmer (PR) is
inluded in the basic version of the welding set ( the PR time can be adjus-
ted on the printed circuit by potentionieter P8).