Alarm
Possible cause
Overheating of the smoke.
Overheating in the hopper.
The hopper is empty.
Problem with the thermal
element or poor contact
with the anode and
cathode.
Pressure switch problem
or exhaust pipe with not
enough vacuum pressure.
Problem with the tempera-
ture sensor or bad contact.
Suggested solution
Reduce the pellet supply of
the screw motor.
Reduce the pellet supply of
the screw motor.
Error at the temperature
control switch in the
hopper. Have the switch
replaced.
Fill the hopper and start
the heater.
Check the contacts of the
thermal element
Have the thermal element
replaced.
Check or change the
pressure switch again.
Check or replace the
exhaust engine.
Check and close the door.
Check and clean the
exhaust pipes.
Check the contacts.
Check the temperature
sensor.