10. Unwind the pressure knob and remove the sample bag. Check the tem-
perature of the sample inside the bag using the tester's thermometer.
11. Refer to the temperature correction table on the log chart for the
material being tested. Apply the temperature correction factor to the
log reading according to the chart. IMPORTANT: APPLY TEMPERA-
TURE CORRECTION TO LOG READING BEFORE LOOKING UP
MOISTURE OR DRY MATTER %.
12. Refer to the proper log chart of the material under test. Read Mois-
ture or Dry Matter content where the CORRECTED log reading and
number of turns intersect.
WARRANTY AND REPAIR INFORMATION
1. THE WARRANTY ON YOUR TESTER IS NOT EFFECTIVE UNLESS
YOU PROVIDE PROOF OF PURCHASE.
2. If your 1210 tester should display inaccurate readings or cease to
operate, follow these steps:
EXAMPLE: When testing fresh green chopped alfalfa, the
"Green Chopped Alfalfa Chart" should be used. If the sample
log reading is 57.4, and the sample temperature is 81˚F
(27˚C), first adjust the log reading for temperature by –3.5.
(The temperature is halfway between a correction of –2 and
–5). The corrected log reading is 57.4 – 3.5 = 53.9. If the
number of turns is just under 5, then the moisture content of
the sample is about 54.5%.
As a helpful guide, all silage log charts for fresh, chopped
forage are presented as % MOISTURE. Charts for ensiled
silage are presented as % DRY MATTER.
Review the Operator's Manual to be sure correct testing
procedures are being used.
Replace battery.
Call our Customer Service department toll-free at 1-800-821-
9542 between 8:30 a.m. and 4:30 p.m. EST. Describe your
problem to service personnel, so that a determination can
be made as to what is wrong with your tester. If necessary,
arrangements can be made for repair or replacement. Make
sure to have your 1210's serial number available.
If service is required and return authorization has been obtained,
pack the tester carefully and return it to Agratronix prepaid.
Enclose a brief note describing what is wrong with your tes-
ter, name, address and phone number.
Do not return your 1210 without following the above pro-
cedure. There will be a handling charge made on all units
returned and not found to be defective.
Repairs will be made free of charge during the warranty
period. After the warranty expires, your tester will be repaired
for the cost of materials, labor and shipping.
- 5 -