2.4. Configuring the LoRaWAN SENSORS unit (analog input)

In this configuration, the device send a periodic data frame following the choosen setting. This mode is only available when the analog type of
sensor are selected for both ways.
our LoRaWAN SENSORS is configured via the combination of switches. The following settings can be changed:
Transmission interval
Inputs activation (sensors 1 and 2)
The type of sensor connected
CONFIGURATION TABLE:
Parameter
Transmission period
(Ony available
on Analog Input Mode)
Activation of sensor inputs
Sensor Type
PLEASE NOTE: You must set your switches before activating the meters. Once a least one way is activated and the LoRaWAN SENSORS has
been started via magnet, the configuration with the switchs can no longer be possible.
If the configuration has any difference between the switchs and the product register value, the consistency error bit will be set to on in the
frame. This consistency verification is carried out every minute.
Value
12h
30mn
15mn
10mn
Sensors 1&2 inactives
Sensor 1 active
Sensor 2 active
Sensor 1&2 actives
Sensors 1&2 ANA
SW3
SW1
SW2
(Sensor 1)
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON
SW4
SW5
(Sensor 2)
(Sensor 1)
(Sensor 2)
OFF
OFF
ON
ON
OFF
Page
GB
SW6
OFF
35
of 45